INI-CET · Anaesthesia
The Anaesthesia Machine and Workstation PYQs
- 36 live questions in The Anaesthesia Machine and Workstation.
- 2 of 36 questions carry a recorded exam year: 2018, 2019.
- Question set last updated .
36 questions with answers
Colour of nitrous oxide cylinder is?
- Blue
- Blue body with white shoulder
- White
- Black
To prevent combustion during anesthesia what combination is used?
- O2 25% & N2O 75%
- O2 50% & N2O 50%
- O2 25% & He 75%
- O2 75% & N2O 25%
Critical temperature for liquid nitrogen is ?
- 36.5degC
- -20degC
- -147degC
- -242degC
A sevoflurane vaporizer can accurately deliver the dose of an anesthetic agent. It resembles it in which of the following properties?
- Molecular weight
- Oil gas partition coefficient
- Blood gas partition coefficient
- Vapor pressure
Pin index system for oxygen
- 1,5
- 2,5
- 4,5
- 3,5
Gas cylinder with single pin index -
- Oxygen
- Air
- Nitrogen
- Entonox
Pin code index of N2O is-
- 1,6
- 2,5
- 2,6
- 3,5
What is the pressure at which oxygen is stored ?
- 75 psi
- 1600 psi
- 760 psi
- 2200 psi
Minimal mandatory Percentage of oxygen used in general anaesthesia is
- 33%
- 30%
- 21%
- 66%
True about anaesthesia machine – a) Cylinder is a part of high pressure systemb) O2 flush delivers < 35 litc) O2 flush delivers > 35 litd) Pipeline is a part of low pressure system
- a
- bc
- ad
- ac
Oxygen content in anaesthetic mixture is –
- 25%
- 30%
- 33%
- 38%
Pin index for Air is
- 1,4
- 2,5
- 5
- 1,5
True about anaesthesia breathing circuit is
- Cylinder is a part of high pressure system
- Oxygen flush delivers less than 35 litres
- Oxygen flush delivers more than 135 litres
- Pipelines is a part of low pressure system
True about scavenging action in OT –
- Outlet connection is 22 mm male fitting
- Interface limit pressure is 0 to +2 cm H2O
- The charcoal as an adsorbent should not be used
- Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment
Show answer
D. Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment
Think this answer is wrong? Report itSafety pin index for oxygen cylinder is?
- 2, 5
- 3,5
- 1,5
- 1,4
Central gas supplies may be located at all of the following places except:-
- Inside in a special room used only for this purpose
- Outdoors
- In an enclosure
- In a non sterile area in the operational theatre
Color of nitrous oxide cylinder is
- Black with white shoulders
- White with black shoulders
- Grey
- Blue
Which of the following is true about anesthesia machine
- Desflurane vapourizer is heated to 39degC
- Halothane vaporizers at 39degC
- Rotameter is a variable pressure flow meter & variable orifice device for gases only
- O2 sensor is attached to inspiratory limb at the machine end.
For high pressure storage of compressed gases cylinders are made up of –
- Molybdenum steel
- Iron + Mo
- Steel + Cu
- Cast iron
What is the critical temperature of N2O
- 118 degrees
- -88 degrees
- 26 degrees
- 36.5 degrees
Colour of oxygen cylinder is –
- Grey
- Blue
- Black with white shoulder
- Orange
All statements are true about gas cylinders except
- Pressure of N2O is 745 psig at 20 degrees centigrade
- Higher pressure indicates impurity in N2O
- N2O is in liquid form
- Emergency oxygen 'E' cylinder has more gas than 'H' cylinder
Show answer
D. Emergency oxygen 'E' cylinder has more gas than 'H' cylinder
Think this answer is wrong? Report itReynolds number is related to
- Laminar flow
- Ventimask
- Dissolved oxygen in blood
- Intraalveolar tension
Which of the following statements about Anaesthetic Machine is true –
- Temperature of Desflurane Vaporizer Chamber is 39°C
- Flow-meters (Rotameters) are Interchangeable
- Oxygen sensors are placed on the expiratory limb of the anesthesia circuit
- All of the above
Show answer
A. Temperature of Desflurane Vaporizer Chamber is 39°C
Think this answer is wrong? Report itPIN index is a safety measure for gas cylinders. What is the PIN index for nitrous oxide?
- 3, 6
- 2, 5
- 3, 5
- 1, 6
Color of N2O cylinder is –
- Black with white shoulders
- White with black shoulders
- Grey
- Blue
Physical law made use of in the electromagnetic flow meter (used to measure blood flow) is:-
- Henrys law
- Grahams law
- Daltons law
- Faraday'slaw
All of the following are safety measures to prevent the delivery of hypoxic gas mixture to the patient except –
- Location of oxygen valve after the N2O valve
- Presence of a PIN index system to prevent wrong attachment of the N2O and oxygen cylinders
- Location of a fail-safe valve downstream from the nitrous oxide supply source
- Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers
Show answer
D. Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers
Think this answer is wrong? Report itAll except one belongs to intermediate pressure system of anaesthetic machine
- Emergency oxygen flush
- Yoke assembly system
- Pipeline pressure gauge
- Pipeline supply
Colour of Entonox cylinder is
- Black body, white shoulder
- Grey body, black and white shoulder
- Black body, brown and white shoulder
- Blue body, white shoulder
Arrange following parts of Anesthesia machine according increasing pressure system wise i) Vaporize mounting devices ii) Hanger yoke assembly iii) Flow indicators iv) Pipe line indicator
- (iii), (i), (iv), (ii)
- (i), (iv), (iii), (ii)
- (ii), (i), (iii), (iv)
- (iii), (iv), (ii), (i)
True about anesthesia cylinders is all except:
- Most commonly used cylinders is type E
- DISS is the safety mechanism to prevent wrong fitting of cylinder to machine
- Cylinders are part of high pressure syste
- Air is stored in cylinder with grey body with black and white shoulder
Show answer
B. DISS is the safety mechanism to prevent wrong fitting of cylinder to machine
Think this answer is wrong? Report itCharacteristic of an ideal gas is
- Volume is directly proportional to change in pressure
- Volume is inversely proportional to change in temperature
- At absolute temp. volume of gas is 1
- Obeys Carles, Byles and Avagadro' laws
Colour coding of halothane , isoflurane, sevoflurane and desflurane is respectively
- red, purple, blue , yellow
- red , purple, yellow , blue
- red , yellow, purple, blue
- red, blue , purple, yellow
Pin code indexof N2O is-
- 1,6
- 2,5
- 2,6
- 3,5
Oxygen cylinder color:
- Black body white shoulder
- White body black shoulder
- Brown body and shoulder
- Blue body and shoulder
Answer key
- A Blue
- C O2 25% & He 75%
- C -147degC
- D Vapor pressure
- B 2,5
- D Entonox
- D 3,5
- D 2200 psi
- B 30%
- D ac
- C 33%
- D 1,5
- A Cylinder is a part of high pressure system
- D Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment
- A 2, 5
- D In a non sterile area in the operational theatre
- D Blue
- A Desflurane vapourizer is heated to 39degC
- A Molybdenum steel
- D 36.5 degrees
- C Black with white shoulder
- D Emergency oxygen 'E' cylinder has more gas than 'H' cylinder
- A Laminar flow
- A Temperature of Desflurane Vaporizer Chamber is 39°C
- C 3, 5
- D Blue
- D Faraday'slaw
- D Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers
- B Yoke assembly system
- D Blue body, white shoulder
- A (iii), (i), (iv), (ii)
- B DISS is the safety mechanism to prevent wrong fitting of cylinder to machine
- D Obeys Carles, Byles and Avagadro' laws
- B red , purple, yellow , blue
- D 3,5
- A Black body white shoulder
About these questions
Previous year questions on The Anaesthesia Machine and Workstation for INI-CET (Institutes of National Importance Combined Entrance Test), from the Anaesthesia section of the exam.
Most questions here come from previous-year papers of Indian postgraduate medical entrance and licensing exams; where a paper and year are recorded the question carries them. The image-based questions are original vignettes written around an openly licensed figure, and were never asked in any exam.
Anaesthesia is worth about 6 of the 200 questions on the exam. See every subject’s weightage.