NEET PG · Community Medicine
Disinfection and Sterilization Methods PYQs
- 45 live questions in Disinfection and Sterilization Methods.
- 3 of 45 questions carry a recorded exam year: 2017, 2018, 2019.
- Question set last updated .
45 questions with answers
Which of the following PPE (Personal Protective Equipment) is removed first?
- Gloves
- Face shield
- Gown
- Mask
Biological indicator for determining efficacy of autoclaving is
- Pseudomonas aeruginosa
- Clostridium perfringenes
- Bacillus stearothermophilus
- Salmonella typhi
Blood on OT floor is cleaned by?
- Phenol
- Alcohol based compounds
- Chlorine based compounds
- Quaternary ammonium compounds
Pasteurization is done at:
- 73degC for 20 minutes
- 63degC for 30 minutes
- 94degC for 20 minutes
- 100degC for 10 minutes
sterilization accuracy is assessed by using ?
- clostridium perfringens
- geobacillus stearothermophilus
- clostridium butyricum
- bacillus subtilis
Culture media containing egg or serum is typically sterilized by using
- Tyndallization
- Autoclaving
- Hot air oven
- 5 % Cresol
Holding time for sterilisation in a hot air oven at a temperature of 180°C is:
- 15 min
- 30 min
- 60 min
- 120 min
In Hot air Oven, for holding period of one hour temperature required is?
- 100oC
- 120oC
- 140oC
- 160oC
Main disadvantage of dry heat used for sterilization is that:
- It is time consuming
- Rusts the instruments
- Dulls the sharp instruments
- Ineffective sterilization
Dry heat destroys microorganisms by
- Lysis
- Oxidation
- Hydrolysis of DNA
- Coagulation of proteins
Patient's cross-infection with sensor, in digital radiography/RVG is prevented by
- Cover with autoclaved cloth with each use
- Wipe with ethyl alcohol in each patient
- Clean with 5.25% sodium hypochlorite in each patient
- Cover with impervious barrier
Compared with autoclave, use of a dry heat oven for sterilization has the following disadvantage:
- Time-consuming
- Less effective
- Causes instruments to rust
- Causes sharp instruments to dull
Which of the following is not used as a disinfectant?
- 1-2% Cetrimide
- 100% Alcohol
- 2% Lysol
- 5% Chloroxylene
Patient's cross infection with bite block of orthopantamograph machine is prevented by
- Cover with autoclaved cloth with each use
- Using disposable bite blocks
- Clean with 5.25% sodium hypochlorite in each patient
- Cover with impervious barrier
Which of the following is not true of boiling water
- It can kill hepatitis B virus
- Used for sterilizing surgical instruments
- Can kill mycobacterium tuberculosis
- Can kill vegetative bacterial cells
The bronchoscope is best sterilized with
- Ethylene oxide
- 2% Glutaraldehyde
- Betadine
- Infrared radiation
Disinfection by autoclaving is NOT recommended for-
- Sputum
- Linen
- Sharp instruments
- All
Most important measure to prevent hospital infection -
- Use of antibiotics
- Use of antiseptics
- Proper hand washing
- Formalin fumigation
Which is false regarding Spaulding's criteria?
- Non critical items require only decontamination
- Semi critical items are those which come in contact with mucous membrane or non intact skin
- Semi critical items need low level disinfection
- Cardiac catheters are examples of critical items
Disinfection of sputum is done by -a) Boilingb) Autoclavingc) Sunlightd) Burninge) Airing
- ae
- edb
- abd
- bd
Most effective sterilizing agent
- Hot air oven
- Auto claving
- Chemical disinfection
- Incineration
Disinfectants used for blood spills-
- Phenol
- Glutaraldehyde
- Ethanol
- Sodium hypochlorite
Most important measure to prevent hospital infection ?
- Use of antibiotics
- Use of antiseptics
- Proper hand washing
- Formalin fumigation
Heart-lung machines are sterilized by?
- Glutaraldehyde
- Ethylene oxide
- Carbolic acid
- Aqueous solution of iodine
Which of the following is used as a control during sterilization of ionizing radiations
- Bacillus stearothermophilus
- Bacillus anthracis
- Bacillus subtilis
- Bacillus pumilus
True about hand hygiene-
- Betadine never causes skin irritation
- Alcohol based preparation are used
- Hot water is best
- Gluteraldehyde is used
Which of the following is true about pasteurization?
- It kills all bacteria and spores
- It kills all bacteria except thermoduric bacteria
- It kills 95% of microorganisms
- All bacteria are destroyed
Show answer
B. It kills all bacteria except thermoduric bacteria
Think this answer is wrong? Report itIrradiation can be used to sterilize all except :
- Bone graft
- Suture
- Artificial tissue graft
- Bronchoscope
The disposable plastic syringes are best sterilized by?
- Formaldehyde
- Ethylene oxide
- Hexachloride
- UV radiation
Endoscope tube is sterilized by:
- Glutaraldehyde
- Formalin
- Autoclaving
- Boiling
Percentage of glutaraldehyde used -
- 1%
- 2%
- 3%
- 4%
False about Ethylene oxide is
- It has high penetration power
- It is highly inflammable
- Sterilization control used is Bacillus pumilus
- Ethylene oxide is irritant and Carcinogenic.
Proctoscope is sterilised by:
- Autoclave
- Glutaraldehyde
- Formalin
- Soap
Operation theatres are sterilized by?
- Carbolic acid spraying
- Washing with soap and water
- Formaldehyde
- ETO gas
The operating temperature in an ethylene oxide sterilization during a warm cycle is -
- 20-35°C
- 49-63°C
- 68-88°C
- 92-110°C
In `Hot air oven' for holding period of one hour, the temperature required is -
- 100°C
- 120°C
- 140°C
- 160°C
Indicator used in autoclave is -
- Clostridium tetani
- Bacillus stearothermophilus
- Bacillus pumilis
- Bacillus subtilis Var Niger
Which of the following is an intermediate level disinfectant?
- Glutaraldehyde
- Quaternary ammonium compound
- Hydrogen peroxide
- Iodophores
Auto claving is done in :
- Dry air at 121 degree C and 15 lb pressure
- Steam at 100 deg C for 30 minutes
- Steam at 121 deg C for 15 minutes
- Dry air at 160 deg C for 30 minutes
Which of the following is best to sterilize heat labile solutions?
- Dry heat
- Autoclave
- Membrane filtration
- Pasteurization
Cold sterilization is ?
- Ionizing radiation
- Mechanical filtration
- Ultrasonic
- Sonic vibrations, heating, then sudden cooling
According spaulding classification system of sterilization, following is true except ?
- "Non-critical devices" come into contact with intact skin
- Semicritical equipment need low-level sterilization
- "Semi-critical devices" come into contact with non-sterile mucous membranes or non-intact skin
- Cardiac catheter is critical equipment
Show answer
B. Semicritical equipment need low-level sterilization
Think this answer is wrong? Report itBacillus stearothermophilus is used as an indicator for-
- Hot air oven
- Radiation
- Gas sterilization
- Autoclaving
Bacillus used to test efficacy of Sterilisation by Autoclave is?
- Bacillus subtilis.
- Bacillus pumilis.
- Bacillus stearothermophilus
- Coxiella burnetti.
Inspissation is used for:
- Sputum
- Protein containing culture medium
- Sugar containing culture medium
- Plasma sterilization
Answer key
- A Gloves
- C Bacillus stearothermophilus
- C Chlorine based compounds
- B 63degC for 30 minutes
- B geobacillus stearothermophilus
- A Tyndallization
- B 30 min
- D 160oC
- A It is time consuming
- B Oxidation
- D Cover with impervious barrier
- A Time-consuming
- B 100% Alcohol
- B Using disposable bite blocks
- B Used for sterilizing surgical instruments
- B 2% Glutaraldehyde
- C Sharp instruments
- C Proper hand washing
- C Semi critical items need low level disinfection
- C abd
- B Auto claving
- D Sodium hypochlorite
- C Proper hand washing
- B Ethylene oxide
- D Bacillus pumilus
- B Alcohol based preparation are used
- B It kills all bacteria except thermoduric bacteria
- D Bronchoscope
- B Ethylene oxide
- A Glutaraldehyde
- B 2%
- C Sterilization control used is Bacillus pumilus
- B Glutaraldehyde
- C Formaldehyde
- B 49-63°C
- D 160°C
- B Bacillus stearothermophilus
- D Iodophores
- C Steam at 121 deg C for 15 minutes
- C Membrane filtration
- A Ionizing radiation
- B Semicritical equipment need low-level sterilization
- D Autoclaving
- C Bacillus stearothermophilus
- B Protein containing culture medium
About these questions
Previous year questions on Disinfection and Sterilization Methods for NEET PG (National Eligibility cum Entrance Test - Postgraduate), from the Community Medicine section of the exam.
Most questions here come from previous-year papers of Indian postgraduate medical entrance and licensing exams; where a paper and year are recorded the question carries them. The image-based questions are original vignettes written around an openly licensed figure, and were never asked in any exam.
Community Medicine is worth about 17 of the 200 questions on the exam. See every subject’s weightage.