NEET PG · Obstetrics & Gynaecology
Assisted Vaginal Delivery: Forceps and Vacuum PYQs
- 35 live questions in Assisted Vaginal Delivery: Forceps and Vacuum.
- Question set last updated .
35 questions with answers
All of the following statements regarding instrumental vaginal delivery are true EXCEPT:
- Forceps are used only at full cervical dilatation
- Forceps may be used when ventouse fails
- Ventouse cannot be used in rotational deliveries of occipito-posterior and occipito-transverse positions
- Forceps can be used in breech deliveries
Show answer
C. Ventouse cannot be used in rotational deliveries of occipito-posterior and occipito-transverse positions
Think this answer is wrong? Report itFenestration in the forceps blade mainly helps in which of the following function?
- Allows blades to grip fetal head firmly
- Protects fetal ears
- Offers smaller metal surface area aganist fetal skull
- Decreases force of traction on maternal vaginal wall
Ideally, traction during vacuum extraction should be applied in which of the following manner?
- Continously
- Intermittently with cycles of 20seconds of traction followed by 1minute of rest
- Intermittently and with contractions
- Intermittently and between contraction
Least complication in outlet forceps is:
- Complete perineal tear
- Vulval hematoma
- Extension of episiotomy
- Cervical tear
All of the following complications are more common in ventouse assisted delivery than forceps except:
- Subgaleal hemorrhage
- Cephalhematoma
- Intracranial hemorrhage
- Transient lateral rectus palsy
Which statements is true regarding VENTOUSE :
- Minor scalp abrasions and subgaleal hematomas in new born are more frequent than forceps
- Can be applied when foetal head is above the level of ischial spine
- Maternal trauma is more frequent than forceps
- Can not be used when fetal head is not fully rotated
Show answer
A. Minor scalp abrasions and subgaleal hematomas in new born are more frequent than forceps
Think this answer is wrong? Report itForceps are applied in all the following except :
- After coming head in breech presentation
- Face presentation
- Occipitoposterior
- Brow presentation
Criteria for Forceps Application include all of the following EXCEPT:
- Fetal head at perineum
- Cervix fully dilated
- Any station below '0'
- Sagittal suture in AP Diameter of Pelvis or < 45 degree short of rotation.
All the following are criteria for outlet forceps application Except
- Fetal skull has reached pelvic floor
- Scalp is visible at the introitus without separating the labia
- Station is between 0 and +2cm
- Rotation does not exceed 45degrees
Vacuum extraction is CONTRAINDICATED in: March 2013
- Premature babies
- Heart disease
- Microcephaly
- Polyhydramnios
True about vacuum extraction of fetus:
- Can be used in nondilated cervix
- Can be used in incompletely dilated cervix
- Used in face presentation
- Applied 3 cm posterior to anterior fontanel
True about instrumental vaginal delivery:
- Full cervical dilatation is the only prerequisite
- Forceps are used in all cases of breech delivery
- Forceps may be used, if ventouse fails
- Ventouse cannot be used in rotational occipito- transverse/posterior delivery
A primigravida is in second stage of labour since 1 hr. On examination the leading point of fetal skull is at +2 station and rotation is 45 degrees short. This can further be managed by
- Applying outlet forceps
- Applying low forceps
- Applying mid forceps
- Applying high forceps
Forceps should NOT be used in:
- Twin delivery
- Hydrocephalus
- Post maturity
- After coming head of breech
Ventouse extraction is done in all except :
- Deep transverse arrest
- After-coming head of breech
- Delay in first stage due to uterine inertia
- Delay in descent of high head in case of second baby of twins
In heart disease, prophylactic forceps is applied at head station of:
- -1
- 1
- 0
- 2
All of the following statements comparing forceps and vacuum (ventouse) delivery are true except
- Vacuum requires more clinical skills than forceps
- Forceps are preferred over vacuum in an HIV-positive patient
- Forceps are more commonly associated with fetal facial injury
- Vacuum has more chance of formation of cephalhematoma
Show answer
A. Vacuum requires more clinical skills than forceps
Think this answer is wrong? Report itConditions Which are relatively contraindicated for vacuum extractions are all; EXCEPT:
- Face presentation
- Extreme prematurity
- Fetal coagulopathies
- Occipito-posterior position
Pressure in ventouse assisted delivery is:
- 0.4 kg/sq.cm
- 0.6 kg/sq.cm
- 0.8 kg/sq.cm
- 1.0 kg/ sq.cm
Outlet forceps, means: a) Head at station "0" b) Full cervical dilatation c) Rupture of membrane d) Rotation > 45
- a
- c
- ac
- bc
All of the following are true regarding forceps and vacuum delivery except:
- Vacuum requires more clinical skills than forceps
- Forceps is preferred over vacuum in HIV-positive mothers when instrumental delivery is needed
- Forceps is more associated with fetal facial injury
- Vacuum has more chance of formation cephalhematoma
Show answer
A. Vacuum requires more clinical skills than forceps
Think this answer is wrong? Report itProphylactic forceps in a cardiac diseased patient is used, when head is at station :
- 0
- 1
- 2
- -1
Which of the following is a prerequisite for ventouse (vacuum extractor) application?
- Intact membranes
- Station +2
- Premature
- Head engaged
Forceps delivery is indicated in all of the following conditions, except
- Face presentation
- Occipitoposterior
- After coming head in breech
- Brow presentation
Vacuum extraction is done when :
- Cervix fully dilated
- Persistent occipito posterior
- Deep transverse arrest
- All
All are complications of vacuum assisted delivery over forceps delivery except
- Cephalhematoma
- Subgaleal hematoma
- Intracranial hemorrhage
- Transient lateral rectus palsy
Contraindication for applying forceps:
- Crowning of head
- Head station +1
- Maternal cardiac disease
- CPD
A forceps rotation of 30 degrees from left occiput anterior (LOA) to occiput anterior (OA) with extraction of fetus from +2 station
- High forceps
- Mid forceps
- Low forceps
- Outlet forceps
Forceps may be applied for delivery for all situations listed below, EXCEPT?
- Sagittal suture of head is 15 degrees short of rotation in pelvis
- Presenting part is face (mento anterior)
- Presenting part is at zero station
- Presence of caput succedaneum
A primigravida is fully dilated with vertex presentation. The head is well rotated and the station is +2. There is late deceleration on fetal heart monitoring. If the pelvis is adequate, the most appropriate management in this case would be :
- Waiting for spontaneous delivery
- Forceps delivery
- Vacuum extraction
- Cesarean section
In instrumental vaginal delivery:
- Full cervical dilatation is the only pre-requisite
- Forceps are used in all cases of breech delivery
- Forceps may be used if ventouse fails
- Ventouse can not be used in rotational occipito-transverse/posterior delivery
All of the following are contraindications of ventouse extraction, EXCEPT:
- Foetal macrosomia
- Face presentation
- Transverse lie
- Anemia
All of the following are true of an outlet forceps application EXCEPT:
- Fetal head at the pelvic floor (perineum) with scalp visible at the introitus
- Full cervical dilatation
- Rupture of membrane
- Rotation > 45
Indications for Forceps delivery are all of the following EXCEPT:
- Mento-anterior Face presentation
- After coming head of breech
- Prolonged second stage of labor
- Intact membrane
A forceps rotation of 30 degrees from left occiput anterior (LOA) to OA with extraction of the fetus from +2 station would be described as which type of delivery?
- Outlet forceps
- Low forceps
- Mid-forceps
- High forceps
Answer key
- C Ventouse cannot be used in rotational deliveries of occipito-posterior and occipito-transverse positions
- A Allows blades to grip fetal head firmly
- C Intermittently and with contractions
- D Cervical tear
- D Transient lateral rectus palsy
- A Minor scalp abrasions and subgaleal hematomas in new born are more frequent than forceps
- D Brow presentation
- C Any station below '0'
- C Station is between 0 and +2cm
- A Premature babies
- B Can be used in incompletely dilated cervix
- C Forceps may be used, if ventouse fails
- B Applying low forceps
- B Hydrocephalus
- B After-coming head of breech
- D 2
- A Vacuum requires more clinical skills than forceps
- D Occipito-posterior position
- C 0.8 kg/sq.cm
- D bc
- A Vacuum requires more clinical skills than forceps
- C 2
- D Head engaged
- D Brow presentation
- D All
- D Transient lateral rectus palsy
- D CPD
- C Low forceps
- C Presenting part is at zero station
- B Forceps delivery
- C Forceps may be used if ventouse fails
- D Anemia
- D Rotation > 45
- D Intact membrane
- B Low forceps
About these questions
Previous year questions on Assisted Vaginal Delivery: Forceps and Vacuum for NEET PG (National Eligibility cum Entrance Test - Postgraduate), from the Obstetrics & Gynaecology section of the exam.
Most questions here come from previous-year papers of Indian postgraduate medical entrance and licensing exams; where a paper and year are recorded the question carries them. The image-based questions are original vignettes written around an openly licensed figure, and were never asked in any exam.
Obstetrics & Gynaecology is worth about 20 of the 200 questions on the exam. See every subject’s weightage.