All are true about Transtracheal Jet ventilation through 14 gauge IV venflon except
- High rate
- High Flow
- Can be given through endotracheal tube
- Can be given through cricothyrotomy
Supreme LMA characteristic is -
- Has no bite block
- Used in infants
- High pressure, low volume
- Has built in drain tube
All of the following are advantages of LMA except-
- More reliable than face mask
- Prevent aspiration
- Alternative to Endotracheal intubation
- Does not require laryngoscope & visualization
Laryngeal mask is contraindicated in all Except
- Oral tumor
- Ocular surgeries
- Massive maxillofacial injury
- High risk of aspiration
Which of the following is not a definitive airway?
- Tracheostomy
- Orotracheal tube
- Nasotracheal tube
- Laryngeal mask airway
Most useful supraglottic airway device in abdominal surgery
- FAST-trach LMA
- PROSEAL LMA
- SLIPA
- C TRACH LMA
Tracheal secretions should be suctioned for:
- 10-15 seconds
- 60 seconds
- 30 seconds
- 3 minutes
Most common sign of airway obstruction
- Slow pounding pulse
- Strenuous breathing
- Increase pulse rate
- Decrease pulse rate
Which of the following is not an indicator of difficult mask ventilation?
- Patient having history of snoring
- Patient having beard
- Old age patient
- Full set of teeth present
The following is true about endotracheal cuff. It has –
- Low volume, high pressure
- Low volume, low pressure
- High volume, low pressure
- Equal volume and pressure
Which of the following is not a definitive airway device-
- Orotracheal Intubation
- Nasotracheal intubation
- LMA
- Tracheostomy
Laryngeal mask airway size 2 is recommended for –
- < 6.5 kg
- 6.5–20 kg
- 20–30 kg
- 30–50 kg
Size of the laryngeal mask airway for normal adults-
- 2.5
- 3
- 1.5
- 4
Which of the following tubes is used in surgery for cleft palate
- Flexometallic tube
- RAE tube
- Robert shaw double lumen tube
Armoured endotracheal tube is used in?
- Cardiovascular surgery
- Neurosurgery
- Thoracic surgery
- Pediatric surgery
Bag and mask ventilation is absolutely contraindicated in –
- Tracheo-esophageal fistula with esophageal atreasia and esophagus connected to trachea
- Diaphragmatic hernia
- Meconium aspiration
- All of the above
All are benefits of laryngeal mask airway except:-
- Easy and fast to insert
- Less hemodynamic imbalance
- Lesser plane of anaesthesia to tolerate
- Prevents aspirations
Advantage of LMA are all except
- Easy to insert
- Aspiration is prevented
- Can be used in cervical trauma
- Does not require muscle relaxant
The laryngeal mask airway used for securing the airway of a patient in all of the following conditions except
- In a difficult intubaton
- In cardiopulmonary resuscitation
- In a child undergoing an elective \/ routine eye sugery
- In a patient with a large tumour in the oral cavity
Show answer
D. In a patient with a large tumour in the oral cavity
Think this answer is wrong? Report itMurphy's eye is part of which of the following devise:-
- Endotracheal tube
- Laryngeal mask airway
- Anesthesia face mask
- Mapleson circuit
In infant (full term) diameter (mm) length (cm) of ETT used are
- 3.5, 16
- 7,12
- 3.5, 12
- 7,10
For 30 kg adult the size of laryngeal mask airway most appropriate is:-
- 3
- 2.5
- 4
- 5
Which of the following prevents aspiration?
- LMA
- Oropharyngeal airway
- Nasopharyngeal airway
- Proseal LMA
All true about armoured endotracheal tube except
- These are tube with metal wire coil embedded in the wall of the tube shaft.
- It has radiopaque line like normal ETT
- It is bend resistant
- It has slightly thicker outer wall as compared to normal ETT
Endotracheal tube size in a full term infant?
- 2.5 mm
- 3.5 mm
- 4.5 mm
- 5.5 mm
Laryngeal mask airway not used in -
- Baby weighing < l500gms
- Pregnant Patients
- Ocular Surgeries
- Difficult airway
All true about Laryngeal mask airway (LMA) except
- The invention of the device is by Dr Archie Brain
- It is composed of a small "mask' designed to sit in the hypo pharynx
- It allows positive - pressure ventilation with upto 20 cm H2O
- Cuff pressure 60 cm H2O of laryngeal mask can adequate prevent aspiration
Show answer
D. Cuff pressure 60 cm H2O of laryngeal mask can adequate prevent aspiration
Think this answer is wrong? Report itLaryngeal mask Airway (LMA) is used for –
- Maintenance of the airway
- Facilitating laryngeal surgery
- Prevention of aspiration
- Removing oral secretions
Which supraglottic airway devise offers maximum airway seal during positive pressure ventilation:-
- LMA proseal
- LMA classic
- Igel
- Laryngeal tube
Size of LMA used for 25kg child is
- 1
- 1.5
- 2.5
- 4
The proseal LMA has advantage over normal LMA
- In being more easy to insert
- Comparable to endotracheal tube in preventing aspiration
- Can be inserted in concious patient.
- Can be used for pulmonary toileting
Show answer
B. Comparable to endotracheal tube in preventing aspiration
Think this answer is wrong? Report itSupraglottic airway device is contraindicated is all except:-
- Patient with risk of aspiration
- Patient with poor lung compliance
- Patient with limited mouth opening
- Patient under general anesthesia
True about endotracheal cuff – a) Low-volume, high pressureb) Low–volume, low pressurec) High-volume, low pressured) High-volume, high pressuree) Equal-volume, pressure
- a
- ac
- ad
- b
Inner diameter of adult male endotracheal tube is
- 2 mm
- 4 mm
- 6 mm
- 9 mm
Armoured endotracheal tube is used in surgeries all except
- Neurosurgery
- Cleft lip surgery
- Spine surgery
- Neck surgery
Mac Intosh curved blade laryngoscope is a type of
- Indirect laryngoscope
- Direct laryngoscopc
- Bronchoscope
- Video laryngoscope
Answer key
- C Can be given through endotracheal tube
- D Has built in drain tube
- B Prevent aspiration
- B Ocular surgeries
- D Laryngeal mask airway
- B PROSEAL LMA
- A 10-15 seconds
- B Strenuous breathing
- D Full set of teeth present
- C High volume, low pressure
- C LMA
- B 6.5–20 kg
- D 4
- B RAE tube
- B Neurosurgery
- B Diaphragmatic hernia
- D Prevents aspirations
- B Aspiration is prevented
- D In a patient with a large tumour in the oral cavity
- A Endotracheal tube
- C 3.5, 12
- A 3
- D Proseal LMA
- B It has radiopaque line like normal ETT
- B 3.5 mm
- B Pregnant Patients
- D Cuff pressure 60 cm H2O of laryngeal mask can adequate prevent aspiration
- A Maintenance of the airway
- A LMA proseal
- C 2.5
- B Comparable to endotracheal tube in preventing aspiration
- D Patient under general anesthesia
- B ac
- D 9 mm
- B Cleft lip surgery
- B Direct laryngoscopc
About these questions
Previous year questions on Devices for Airway Management for NEET PG (National Eligibility cum Entrance Test - Postgraduate), from the Anaesthesia section of the exam.
Most questions here come from previous-year papers of Indian postgraduate medical entrance and licensing exams; where a paper and year are recorded the question carries them. The image-based questions are original vignettes written around an openly licensed figure, and were never asked in any exam.
Anaesthesia is worth about 4 of the 200 questions on the exam. See every subject’s weightage.