PYQPrep

NEET PG · Anaesthesia

The Anaesthesia Machine and Workstation PYQs

Practise all 36 on a timer

36 questions with answers

  1. Q1
    • FMGE 2019

    Colour of nitrous oxide cylinder is?

    1. Blue
    2. Blue body with white shoulder
    3. White
    4. Black
    Show answer

    A. Blue

    Think this answer is wrong? Report it
  2. Q2
    • JIPMER 2018

    To prevent combustion during anesthesia what combination is used?

    1. O2 25% & N2O 75%
    2. O2 50% & N2O 50%
    3. O2 25% & He 75%
    4. O2 75% & N2O 25%
    Show answer

    C. O2 25% & He 75%

    Think this answer is wrong? Report it
  3. Q3
    • All India

    Critical temperature for liquid nitrogen is ?

    1. 36.5degC
    2. -20degC
    3. -147degC
    4. -242degC
    Show answer

    C. -147degC

    Think this answer is wrong? Report it
  4. Q4
    • PG Entrance

    A sevoflurane vaporizer can accurately deliver the dose of an anesthetic agent. It resembles it in which of the following properties?

    1. Molecular weight
    2. Oil gas partition coefficient
    3. Blood gas partition coefficient
    4. Vapor pressure
    Show answer

    D. Vapor pressure

    Think this answer is wrong? Report it
  5. Pin index system for oxygen

    1. 1,5
    2. 2,5
    3. 4,5
    4. 3,5
    Show answer

    B. 2,5

    Think this answer is wrong? Report it
  6. Gas cylinder with single pin index -

    1. Oxygen
    2. Air
    3. Nitrogen
    4. Entonox
    Show answer

    D. Entonox

    Think this answer is wrong? Report it
  7. Pin code index of N2O is-

    1. 1,6
    2. 2,5
    3. 2,6
    4. 3,5
    Show answer

    D. 3,5

    Think this answer is wrong? Report it
  8. What is the pressure at which oxygen is stored ?

    1. 75 psi
    2. 1600 psi
    3. 760 psi
    4. 2200 psi
    Show answer

    D. 2200 psi

    Think this answer is wrong? Report it
  9. Minimal mandatory Percentage of oxygen used in general anaesthesia is

    1. 33%
    2. 30%
    3. 21%
    4. 66%
    Show answer

    B. 30%

    Think this answer is wrong? Report it
  10. True about anaesthesia machine – a) Cylinder is a part of high pressure systemb) O2 flush delivers < 35 litc) O2 flush delivers > 35 litd) Pipeline is a part of low pressure system

    1. a
    2. bc
    3. ad
    4. ac
    Show answer

    D. ac

    Think this answer is wrong? Report it
  11. Oxygen content in anaesthetic mixture is –

    1. 25%
    2. 30%
    3. 33%
    4. 38%
    Show answer

    C. 33%

    Think this answer is wrong? Report it
  12. Pin index for Air is

    1. 1,4
    2. 2,5
    3. 5
    4. 1,5
    Show answer

    D. 1,5

    Think this answer is wrong? Report it
  13. True about anaesthesia breathing circuit is

    1. Cylinder is a part of high pressure system
    2. Oxygen flush delivers less than 35 litres
    3. Oxygen flush delivers more than 135 litres
    4. Pipelines is a part of low pressure system
    Show answer

    A. Cylinder is a part of high pressure system

    Think this answer is wrong? Report it
  14. True about scavenging action in OT –

    1. Outlet connection is 22 mm male fitting
    2. Interface limit pressure is 0 to +2 cm H2O
    3. The charcoal as an adsorbent should not be used
    4. Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment
    Show answer

    D. Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment

    Think this answer is wrong? Report it
  15. Safety pin index for oxygen cylinder is?

    1. 2, 5
    2. 3,5
    3. 1,5
    4. 1,4
    Show answer

    A. 2, 5

    Think this answer is wrong? Report it
  16. Central gas supplies may be located at all of the following places except:-

    1. Inside in a special room used only for this purpose
    2. Outdoors
    3. In an enclosure
    4. In a non sterile area in the operational theatre
    Show answer

    D. In a non sterile area in the operational theatre

    Think this answer is wrong? Report it
  17. Color of nitrous oxide cylinder is

    1. Black with white shoulders
    2. White with black shoulders
    3. Grey
    4. Blue
    Show answer

    D. Blue

    Think this answer is wrong? Report it
  18. Which of the following is true about anesthesia machine

    1. Desflurane vapourizer is heated to 39degC
    2. Halothane vaporizers at 39degC
    3. Rotameter is a variable pressure flow meter & variable orifice device for gases only
    4. O2 sensor is attached to inspiratory limb at the machine end.
    Show answer

    A. Desflurane vapourizer is heated to 39degC

    Think this answer is wrong? Report it
  19. For high pressure storage of compressed gases cylinders are made up of –

    1. Molybdenum steel
    2. Iron + Mo
    3. Steel + Cu
    4. Cast iron
    Show answer

    A. Molybdenum steel

    Think this answer is wrong? Report it
  20. What is the critical temperature of N2O

    1. 118 degrees
    2. -88 degrees
    3. 26 degrees
    4. 36.5 degrees
    Show answer

    D. 36.5 degrees

    Think this answer is wrong? Report it
  21. Colour of oxygen cylinder is –

    1. Grey
    2. Blue
    3. Black with white shoulder
    4. Orange
    Show answer

    C. Black with white shoulder

    Think this answer is wrong? Report it
  22. All statements are true about gas cylinders except

    1. Pressure of N2O is 745 psig at 20 degrees centigrade
    2. Higher pressure indicates impurity in N2O
    3. N2O is in liquid form
    4. Emergency oxygen 'E' cylinder has more gas than 'H' cylinder
    Show answer

    D. Emergency oxygen 'E' cylinder has more gas than 'H' cylinder

    Think this answer is wrong? Report it
  23. Reynolds number is related to

    1. Laminar flow
    2. Ventimask
    3. Dissolved oxygen in blood
    4. Intraalveolar tension
    Show answer

    A. Laminar flow

    Think this answer is wrong? Report it
  24. Which of the following statements about Anaesthetic Machine is true –

    1. Temperature of Desflurane Vaporizer Chamber is 39°C
    2. Flow-meters (Rotameters) are Interchangeable
    3. Oxygen sensors are placed on the expiratory limb of the anesthesia circuit
    4. All of the above
    Show answer

    A. Temperature of Desflurane Vaporizer Chamber is 39°C

    Think this answer is wrong? Report it
  25. PIN index is a safety measure for gas cylinders. What is the PIN index for nitrous oxide?

    1. 3, 6
    2. 2, 5
    3. 3, 5
    4. 1, 6
    Show answer

    C. 3, 5

    Think this answer is wrong? Report it
  26. Color of N2O cylinder is –

    1. Black with white shoulders
    2. White with black shoulders
    3. Grey
    4. Blue
    Show answer

    D. Blue

    Think this answer is wrong? Report it
  27. Physical law made use of in the electromagnetic flow meter (used to measure blood flow) is:-

    1. Henrys law
    2. Grahams law
    3. Daltons law
    4. Faraday'slaw
    Show answer

    D. Faraday'slaw

    Think this answer is wrong? Report it
  28. All of the following are safety measures to prevent the delivery of hypoxic gas mixture to the patient except –

    1. Location of oxygen valve after the N2O valve
    2. Presence of a PIN index system to prevent wrong attachment of the N2O and oxygen cylinders
    3. Location of a fail-safe valve downstream from the nitrous oxide supply source
    4. Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers
    Show answer

    D. Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers

    Think this answer is wrong? Report it
  29. All except one belongs to intermediate pressure system of anaesthetic machine

    1. Emergency oxygen flush
    2. Yoke assembly system
    3. Pipeline pressure gauge
    4. Pipeline supply
    Show answer

    B. Yoke assembly system

    Think this answer is wrong? Report it
  30. Colour of Entonox cylinder is

    1. Black body, white shoulder
    2. Grey body, black and white shoulder
    3. Black body, brown and white shoulder
    4. Blue body, white shoulder
    Show answer

    D. Blue body, white shoulder

    Think this answer is wrong? Report it
  31. Arrange following parts of Anesthesia machine according increasing pressure system wise i) Vaporize mounting devices ii) Hanger yoke assembly iii) Flow indicators iv) Pipe line indicator

    1. (iii), (i), (iv), (ii)
    2. (i), (iv), (iii), (ii)
    3. (ii), (i), (iii), (iv)
    4. (iii), (iv), (ii), (i)
    Show answer

    A. (iii), (i), (iv), (ii)

    Think this answer is wrong? Report it
  32. True about anesthesia cylinders is all except:

    1. Most commonly used cylinders is type E
    2. DISS is the safety mechanism to prevent wrong fitting of cylinder to machine
    3. Cylinders are part of high pressure syste
    4. Air is stored in cylinder with grey body with black and white shoulder
    Show answer

    B. DISS is the safety mechanism to prevent wrong fitting of cylinder to machine

    Think this answer is wrong? Report it
  33. Characteristic of an ideal gas is

    1. Volume is directly proportional to change in pressure
    2. Volume is inversely proportional to change in temperature
    3. At absolute temp. volume of gas is 1
    4. Obeys Carles, Byles and Avagadro' laws
    Show answer

    D. Obeys Carles, Byles and Avagadro' laws

    Think this answer is wrong? Report it
  34. Colour coding of halothane , isoflurane, sevoflurane and desflurane is respectively

    1. red, purple, blue , yellow
    2. red , purple, yellow , blue
    3. red , yellow, purple, blue
    4. red, blue , purple, yellow
    Show answer

    B. red , purple, yellow , blue

    Think this answer is wrong? Report it
  35. Pin code indexof N2O is-

    1. 1,6
    2. 2,5
    3. 2,6
    4. 3,5
    Show answer

    D. 3,5

    Think this answer is wrong? Report it
  36. Oxygen cylinder color:

    1. Black body white shoulder
    2. White body black shoulder
    3. Brown body and shoulder
    4. Blue body and shoulder
    Show answer

    A. Black body white shoulder

    Think this answer is wrong? Report it

Answer key

  1. A Blue
  2. C O2 25% & He 75%
  3. C -147degC
  4. D Vapor pressure
  5. B 2,5
  6. D Entonox
  7. D 3,5
  8. D 2200 psi
  9. B 30%
  10. D ac
  11. C 33%
  12. D 1,5
  13. A Cylinder is a part of high pressure system
  14. D Scavenging is defined as the collection of excess gases from equipment used in administrating anesthesia or exhaled by the patient and removal of these gases to an appropriate places discharge outside the working environment
  15. A 2, 5
  16. D In a non sterile area in the operational theatre
  17. D Blue
  18. A Desflurane vapourizer is heated to 39degC
  19. A Molybdenum steel
  20. D 36.5 degrees
  21. C Black with white shoulder
  22. D Emergency oxygen 'E' cylinder has more gas than 'H' cylinder
  23. A Laminar flow
  24. A Temperature of Desflurane Vaporizer Chamber is 39°C
  25. C 3, 5
  26. D Blue
  27. D Faraday'slaw
  28. D Presence of a vaporizer interlock system to prevent simultaneous use of two vaporizers
  29. B Yoke assembly system
  30. D Blue body, white shoulder
  31. A (iii), (i), (iv), (ii)
  32. B DISS is the safety mechanism to prevent wrong fitting of cylinder to machine
  33. D Obeys Carles, Byles and Avagadro' laws
  34. B red , purple, yellow , blue
  35. D 3,5
  36. A Black body white shoulder

About these questions

Previous year questions on The Anaesthesia Machine and Workstation for NEET PG (National Eligibility cum Entrance Test - Postgraduate), from the Anaesthesia section of the exam.

Most questions here come from previous-year papers of Indian postgraduate medical entrance and licensing exams; where a paper and year are recorded the question carries them. The image-based questions are original vignettes written around an openly licensed figure, and were never asked in any exam.

Anaesthesia is worth about 4 of the 200 questions on the exam. See every subject’s weightage.

All 26 topics in Anaesthesia PYQs